Daily Flushing Procedure

To avoid fire and explosion, always ground the entire
system, including the gun and waste container. To
avoid static sparking and injury from splashing,
always flush at the lowest possible pressure and
maintain metal to metal contact between the gun and
flushing pail.
NOTE: Flush the pump and gun before the fluid can dry
in it.
NOTE: If it is available, the flushing procedure provided
in the pump or sprayer manual should be used instead
of this procedure.
1. Follow Pressure Relief Procedure, page 12.
311053L
2. Remove the spray tip. Clean the parts.
3. Supply a compatible solvent to the gun fluid inlet.
4. Start the pump and operate it at its lowest pressure.
5. Trigger the gun into a grounded metal waste
container until all the material is removed from the
gun passages.
F
. 14: Trigger Gun into Grounded Metal Container
IG
6. Follow Pressure Relief Procedure, page 12.
7. Disconnect the solvent supply.