PerformAA RAC SwitchTips

PerformAA RAC models are compatible with the
following RAC spray tips:
LTX RAC Spray Tips (LTXxxx): Recommended for
high pressure RAC spray gun models.
FFLP Fine Finish Low Pressure (FFLPxxx):
Recommended for low pressure, fine finish applications
for less over-spray and a consistent finish.
LTX and FFLP SwitchTips are the typical tips chosen,
but the PerformAA RAC is also compatible with Low
Pressure (LPxxxx) and Wide (WRxxxx) tips.
* Fluid Output
2000 psi
(14.0 MPa, 140
Orifice Size in.
bar)
(mm)
fl oz/min (lpm)
LTX RAC Spray Tips
0.009 (0.229) 11.2 (0.33)
0.011 (0.279) 16.6 (0.49)
0.013 (0.330) 23.3 (0.69)
0.015 (0.381) 30.8 (0.91)
0.017 (0.432) 39.5 (1.17)
0.019 (0.483) 49.7 (1.47)
0.021 (0.533) 60.5 (1.79)
0.023 (0.584) 72.7 (2.15)
0.025 (0.635) 85.9 (2.54)
0.027 (0.686) 100.0 (2.96)
0.029 (0.737) 115.6 (3.42)
0.031 (0.787) 131.8 (3.90)
0.033 (0.838) 149.4 (4.42)
0.035 (0.889) 168.4 (4.98)
FFLP Fine Finish Low Pressure RAC Spray Tips
0.008 (0.203) 8.8 (0.26)
0.010 (0.254) 13.9 (0.41)
0.012 (0.305) 19.9 (0.59)
0.014 (0.356) 27.0 (0.80)
0.016 (0.406)
0.018 (0.457)
0.020 (0.51)
*Tips are tested in water.
Measured with NO airflow. Air assist will tend to reduce pattern lengths by 1 in. to 2 in.
Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT)
output (fl oz/min) from the above table for the selected orifice size.
.
3A8099A
 Maximum Pattern Width at 12 in. (305 mm)
2 to 4 (100) 4 to 6 (150)
109
209
111
211
---
213
115
215
---
217
---
219
---
221
---
---
---
225
---
227
---
---
---
231
---
---
---
235
108
208
110
210
112
212
---
214
---
---
---
---
---
---
Order desired tip, where xxx = 3-digit spray tip Part No.
from the matrix table. Example: Order LTX209 for the
LTX RAC Spray tip with a 0.009 in. (0.229 mm) orifice
and a maximum spray pattern of
Convert PerformAA 50 models to a RAC Model with
RAC Conversion Kit 24C791. Standard and acetal
(solvent resistant) gasket kits are available. See
Reverse-a-Clean Kits, page 56.
in. (mm)
6 to 8
8 to 10
10 to 12
(200)
(250)
(300)
Spray Tip Part No.
309
409
509
311
411
511
313
413
513
315
415
515
317
417
517
319
419
519
321
421
521
323
423
523
325
425
525
327
427
527
329
429
529
331
431
531
---
433
533
335
435
535
308
---
---
310
410
510
312
412
512
314
414
514
---
---
516
---
---
518
---
---
520
Spray Tip Charts
2 to 4 in. (100 mm).
12 to 14
14 to 16
16 to 18
(350)
(400)
---
---
611
---
613
---
615
---
617
---
619
---
621
721
623
723
625
---
627
---
629
729
631
---
633
---
635
735
---
---
---
---
612
---
614
---
616
---
618
---
620
---
where QT = fluid
P
(450)
---
---
---
---
817
819
821
---
---
827
831
833
835
---
---
---
---
---
---
---
53