Table 1-6 Function Timer Chart - NEC Xen Master Programming Manual

Hide thumbs Also See for Xen Master:
Table of Contents

Advertisement

S
5
ECTION
F
T
UNCTION
IMER
C
HART
Timer
Pause Time Selection
DP Interdigit Time
Selection
Hookflash Time
Selection
Hold Recall Timer
Selection
(Non-Exclusive Hold)
Automatic Redial
Time Selection
Start Timer Selection
CO/PBX Incoming
Ringing Alarm Time
Selection
Tie Line Delay
Ringing Timer
Selection
Station Transfer/
Camp-On Recall
Timer Selection
Trunk Queuing
Timeout Selection
CO/PBX Prepause
Timer Selection
Hold Recall Time
Selection (Exclusive)
Programming Manual
The chart on the following pages provides a list of timers that can be programmed
in the system. The information is listed numerically by Memory Block number. A
brief definition and the timing value is given for each timer.
New Zealand - Analogue CO Trunks do not support the Scroll Feature or DP
Dialling.

Table 1-6 Function Timer Chart

Memory
Definition
Block
1-1-00
Duration when no signal is being
sent to a CO/PBX line.
1-1-01
Minimum interval between dialling
signals in Dial Pulse dialling.
1-1-02
Timing of a CO/PBX hookflash
from the Recall key of a Multiline
Terminal or a Single Line
Telephone to the CO/PBX line.
1-1-03
Specify the time before a held
CO/PBX line recalls the station that
put that line on hold.
1-1-04
Defines the redial timing
parameters when automatic redial
is set to a busy CO/PBX number.
1-1-05
Specify the time for after dialling
and the start of call duration
display and Talk Start Timer.
1-1-06
Specify the time from receiving an
incoming CO/PBX call until the
ringing tone changes to a different
ringing tone level if the call is not
answered.
1-1-07
Specify the delay interval between
the time a telephone rings
(accessed by a ringing call in the
Tie/DID line) and the time other
telephones start ringing.
1-1-12
The time before a ring transferred
call recalls to the station that
transferred the call.
1-1-37
Specify the time queuing for a
CO/PBX line recalls before being
automatically cancelled.
1-1-57
Specify the pause time before
dialed digits are sent over a
CO/PBX line.
1-1-63
Specify the time for Exclusive Hold
Recall.
Timing Value
Minimum
Default
1 sec.
3 sec.
650/500 ms.
800/800 ms.
20 ms.
600 ms.
25 sec.
25 sec.
30 sec.
2 sec.
10 sec.
10 sec.
No Limit
10 sec.
No Limit
25 sec.
45 sec.
10 sec.
10 sec.
None
1 sec.
30 sec.
1 min.
May 2003
Maximum
3 sec.
800/800 ms.
5000 ms.
(5 sec.)
No Limit
60 sec.
70 sec.
No Limit
No Limit
No Limit
60 sec.
15 sec.
No Limit
1 - 423