NEC Xen Master Programming Manual page 95

Hide thumbs Also See for Xen Master:
Table of Contents

Advertisement

Programming Manual
CO/PBX Outgoing Digit Add
Assignment
General Description
Use this Memory Block to specify up to 10 additional digits when a trunk in the Trunk Group
or Route Advance block assigned in Memory Block 1-1-49 Networking Trunk Group/Route
Advance Assignment is seized, and a number is dialled.
Display
Closed
Data
Number Block
No.
01~16
5 0 : 0 1 =
T I M E
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1 +
EK
3 Use dial pad to enter digits to be added.
Note: Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
U
to clear all data
Q
J
+
to enter *
Q
+
L
to enter #
N
4 Press
to write selected data.
P
5 Press
to go back on-line.
Related Programming
M.B. Number
1-1-49
Networking Trunk Group/Route Advance Assignment
CO/PBX Outgoing Digit Add Assignment
Add Digit
10 Max. (0~9, *, #)
D I S P L A Y
to access the Memory Block.
Memory Block Name
System Mode
1
Submode
1
Data No.
50
PC Programming
a
+BCS
Default Values
Not Specified
May 2003
1-1-50
1 - 77