Alarms, Deviations, and Advisories
Code
Icon
Code Name
Code
Code
Icon
Icon
Code
Code
Alarms
Alarms
Alarms
WJPX
WJPX
WJPX
Air Solenoid
Disconnected
P4AX
P4AX
P4AX
Pressure A
P4BX
P4BX
P4BX
Pressure B
BATT
BATT
BATT
Low Battery
FUSE
Blown Fuse
FUSE
FUSE
Pressurized
pressure is not turned down. After shutting off the air pressure, press the pin until flush.
* Remote mix manifold applications only.
16
Name
LED Status
Status
Name
LED
LED
Status
Flashing Red
Flashing Red
High
Flashing Red
High
Flashing Red
Flashing Red
System
Flashing Red
System Pressurized Flashing Red Only the XP-hf will have these images if the air
Cause
Cause
Cause
Broken cable.
Disconnected cable.
Damaged solenoid.
A pressure exceeded
maximum working
pressure set point.
A pressure exceeded
maximum working
pressure set point.
Too much restriction
on mix manifold B side
restriction.
Blockage in B line
downstream.
Battery is low.
Fuse is blown.
System is pressurized
when clearing an alarm.
Solution
Solution
Solution
Replace cable.
Connect cable.
Replace solenoid.
Reduce air pressure to
motor or adjust setpoint.
Reduce air pressure to
motor or adjust setpoint.
Open down stream valve.
Reduce restriction to B
side on mix manifold.
Reduce downstream
restriction.
Clean mix manifold.
See
Repair, page
18.
See
Repair, page 18
for
information on how to
check the fuse.
Shut off air pressure and
wait for air pressure to
drop.
3A3320D