Graco 17G807 Operation And Parts page 23

Xp and xp-hf pressuretrak pressuretrak pressuretrak kit
Table of Contents

Advertisement

Setup
Setup Screen
Setup
Screen 2 2 2
Screen
Setup Screen 2 enables the user to set the high
spray pressure alarm limit value, minimum spray
pressure value, and B pressure offset. Refer to the
following table for more information.
3A3320D
Appendix A — User Setup Display
Icon
Function
Icon
Icon
Function
Function
High Pressure
Pressure Limit
High
High
Pressure
Adjust the high pressure limit.
XP
XP Systems:
XP
Systems:
Systems:
Default: 7250 psi (50 MPa, 500 Bar)
Range: 0–7250 psi (50 MPa, 500 Bar)
maximum
XP- - - hf hf hf Systems:
Systems:
XP
XP
Systems:
Default: 7500 psi (52 MPa, 517 Bar)
Range: 0–7500 psi (52 MPa, 517 Bar)
maximum
Minimum Spray
Spray Pressure
Minimum
Minimum
Spray
Adjust the lower spray pressure limit.
Default: 2000 psi (13.8 MPa, 138 Bar)
B B B Side
Side Pressure
Pressure Offset
Side
Pressure
Default: 0 psi (0 MPa, 0 bar)
Range: -999 – +999 psi (-9.9 – +9.9
MPa, -99.9 – 99.9 Bar) maximum
Only used for remote mix manifold
applications where there is a normal
difference in pressure between A and B.
Remote mix manifold applications
should first be balanced with proper
hose sizing and adjusting the mix
manifold B restrictor. See manual
3A0590.
Use this if the differential alarm bar
graph on the Spray Screen is off to one
side under normal spray conditions.
Password
Password
Password
The setup screens can be protected
by a password to restrict their
accessibility. To set the password, see
Set Password, page
the password, enter 0000.
Default: 0000 (not active)
Range: 0–9999
Limit
Limit
Pressure Limit
Limit
Pressure
Limit
Offset
Offset
24. To deactivate
23