Run Screen
Screen Details
Run
Run
Screen
The graph on the bottom of the display shows the
magnitude of the differential pressure in relation to
the deviation and alarm setpoints. If the moving bar
is in the center, clear area of the graph (the pressures
are within tolerance). If the moving bar is in the
dotted area of the graph, the pressures are in the
deviation set point. If the moving bar moves to either
end of the graph, the pressures are in the alarm
setpoint and the PressureTrak Monitor will alarm.

Circulation Mode

Mode
Circulation
Circulation
Mode
This is the display screen that appears after the
power up screen. A and B pressure are shown. In
Circulation Mode, all alarms are disabled except for
the Air Solenoid Disconnected High Pressure A, and
High Pressure B alarms.
Icon
System Status
Icon
Icon
System
System
Indicates that you are in Circulation
Mode and the fluid pressure is
below the Lower Spray Pressure
Limit.
All alarms are disabled except
for Air Solenoid Detection, High
Pressure A, and High Pressure B
alarms.
3A3320D
Details
Details
Status
Status
Spray Mode
Mode Active
Active
Spray
Spray
Mode
Active
This is the display screen that appears during spray
mode. A and B pressure are shown.
When the pressure first gets above the lower spray
pressure limit, the user has 30 seconds to balance
the system differential pressure so it is less than the
differential pressure deviation and alarm limits. Then
the system will automatically go into Spray mode and
start monitoring all alarms and deviations.
Icon
Icon
Icon
System
System
System Status
Indicates that you are in spray
mode, at least one of the pumps
has pressure greater than the
lower spray pressure limit, and the
differential pressure is less that
the differential pressure deviation
setpoint.

Alarm Active

Active
Alarm
Alarm
Active
This is the display screen that appears during an
active alarm. A and B pressures shown are the
current pressures of the system. The information
screen captures the pressure at the time of the alarm.
To toggle between the Alarm Active screen and the
Alarm Information screen, press either the
Refer to the following table for more information.
Icon
Icon
Icon
System Status
System
System
Indicates that there is an active
alarm.

Run Screen Details

Status
Status
Status
Status
25