Configure the NT5D97 DDP2

NT5D97 Dual-port DTI2/PRI2 installation and removal
7
Remove the DDP2 card only if both loops are disabled. If the other circuit
of a DDP2 card is in use, DO NOT remove the card. The Faceplate switch
ENB/DIS must be in the OFF (DIS) position before the card is removed,
otherwise the system will initialize.
8
Pack and store the
After the NT5D97 DDP2 is installed, configure the system using the same
procedures as the standard NT8D72BA PRI2.
Consider the following when configuring the NT5D97 DDP2 card:
The system software allows four ports to be defined for the NT6D80
MSDL. The DDCH (NTBK51AA) card has only two ports, 0 and 1;
therefore, ports 2 and 3 must not be defined when using the NTBK51AA.
Port 0 of the NTBK51AA can only be defined to work with Loop 0 of the
NT5D97 DDP2 card, and Port 1 of the NTBK51AA can only be defined
to work with Loop 1 of the NT5D97. This relationship must be reflected
when configuring a new DCH in LD 17 (in response to the DCHL
prompt, enter either 0 or 1 when specifying the loop number used by the
DCH).
You cannot define one of the DDP2 loops for the NTBK51AA DDCH,
and the other loop for the NT6D11AF, NT5K75AA, and NT5K35AA
DCH card or the NT6D80 MSDL.
When configuring the NT5D97 DDP2 in DTI2 outgoing dial pulse mode,
a Digit Outpulsing patch is required.
ISDN Primary Rate Interface
NT5D97
card and circuit card.
End of Procedure