Install Or Replace A Clock Controller On A Half Group And Single Group System - Nortel Communication Server 1000S Installation And Configuration Manual

Isdn primary rate interface
Hide thumbs Also See for Communication Server 1000S:
Table of Contents

Advertisement

LD 39 commands with the NTRB53 Clock Controller
Command
DIS SCG x
ENL SCG x
SCLK
STAT SCG x
Install or replace a Clock Controller on a Half Group
and Single Group system
Procedure 18 outlines the steps to install a clock controller on Half Group and
Single Group systems.
Procedure 18
Install a clock controller for Half Group and Single Group Systems.
1
Unpack and inspect the circuit card.
2
Determine the cabinet and shelf location. Refer to Table 64 on
3
Set the clock controller switch. Refer to Table 65 on
on
page
4
Set the ENL/DIS toggle switch to DIS (disable).
Clock Controller description and installation
Description
Disable SCG card x (0 or 1).
Not applicable for NTRB53 Clock Controller. Use LD 60
instead.
Enable SCG x (0 or 1).
Not applicable for NTRB53 Clock Controller. Use LD 60
instead.
Switch clock to other SCG.
Functions with NTRB53 Clock Controller
Print status of SCG x (0 or 1).
Prints normal status of NTRB53 (not full status)
209, or Table 67 on
ISDN Primary Rate Interface
page
210.
Installation and Configuration
Page 211 of 394
page
208.
page
209, Table 66

Advertisement

Table of Contents
loading

Table of Contents