Simple Mode –Options
When using "Simple Mode", there are three options that you can set to your preference.
T-Stat Idle Mode
Auto Fan or Manual Fan speed
Heat Output (Pellet Feed Rate)
Screen Lock
 
T-Stat Idle Mode
The stove allows you to select what it will do when the space reaches the temperature set on the thermostat. There are
two choices.
On & Off 
Low Burn 
On & Off Option
The "On & Off" option allows the stove to turn itself off.
When the room temperature drops below the stove
thermostat temperature setting, the stove will begin
another startup cycle and return to normal thermostat
operation.
Low Burn Option
When the stove is set to the "Low Burn" option, it will turn
itself down to its lowest setting when the heating need of
the space has been met. The stove will continue to burn at
that low rate until the thermostat calls for heat again.
When heat is needed, the feed rate will return to the Heat
Setting that is set on the "Heat Setting" slider, until the call
for heat has been satisfied.
Auto-Fan
This feature sets the fan speed to the same setting as the Heat Setting.  If the heater is on high, the fan will 
be on high.  If the heater is on low, the fan will be on low.  When on, the Auto‐Fan Button will display a blue 
LED light. 
Heat Output
The heat output setting determines how quickly pellets will be pushed onto the burn platform and thus how big the fire
is in the firebox. This can be used to help manage how often the stove has to light and shut down (also know as
cycling). If the stove is cycling often, reduce the heat output.
Screen Lock
Use the Screen Lock feature to disable unwanted touch-screen input. This is typically done to prevent children or pets
from inadvertently adjusting the heater.