Venting the Pellet Stove

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR
STOVE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT THROUGH WALLS AND
A CEILING SUPPORT/FIRE STOP SPACER WHEN PASSING THE VENT THROUGH
CEILINGS (MAKE SURE TO MAINTAIN CLEARANCE TO ANY COMBUSTIBLES).
No more than one tee and 180° of elbows (one tee with two 90° elbows, one tee with one 90° and
two 45° elbows, etc.).

Maximum Venting Distance

Vent must have a support bracket
every 5' (1.524 M) of pellet vent when
on exterior of structure.
NOTE: Travis Industries
recommends a minimum vertical vent
of 5' to ensure adequate draft during
a power outage.
© Travis Industries
(For Qualified Installers Only)
The vent height and
run must not exceed
the distance shown in
the shaded region
indicated to the right
Restrictor adjustment
may be required
dependent on the vent
configuration. See the
section "Restrictor
Adjustments" for
details.
Note: To achieve
optimum performance,
we recommend
keeping the vent as
short as possible
(horizontal run
especially).
12/18/20 - 1550
11
40 Feet
(max.)
35 Feet
30 Feet
25 Feet
20 Feet
15 Feet
10 Feet
5 Feet
0 Feet