Synchronous Trigger; Extended Trigger Resolution; Software Trigger - Teledyne ADQ8-4X Manual

Table of Contents

Advertisement

4.6.3

Synchronous trigger

A synchronous trigger is phase locked to the clock of the digitizer. The trigger source needs access to
the clock reference of the digitizer. There are three ways to achieve this synchronization:
1. Output the internal clock reference of the ADQ and send it to the trigger source,
2. Use the clock reference of the trigger source as clock reference for the ADQ,
3. Use the internal trigger of the ADQ and output it to trigger the external equipment,
When the trigger is phase-locked to the clock reference the timing is comparable to a digital signal
which defines setup and hold time.
4.6.4

Extended trigger resolution

The basic sampling process maps the trigger to the sampling rate of the digitizer. There is also addi-
tional trigger time information available; Extended trigger resolution,
The Trigger Clock is operating at 4 GHz. This means that the time resolution of the trigger input TRIG is
reduced to 250 ps.
Note: The extended trigger resolution is available on triggers connected to TRIG only.
The extended trigger information is included in the timestamp information,
 

 
 
Figure 11: Extended trigger resolution timing for ADQ8-4X
The position of the first sample is rounded up from the trigger position. The parameter
tells where the trigger was. Referring to
the range –250 ps up to +500 ps. A positive value means that the first sample is after the trigger. The
given range is without pretrigger or trigger delay. With pretrigger or trigger delay, the
will have a larger (absolute) value.

4.7 Software trigger

The software trigger is a user command that triggers the ADQ. This is for direct user control of the
acquisition and is useful for looking at continuous signals where the timing of the trigger is not critical.
The software trigger is sent through several layers of software and the time when it arrives to the digi-
tizer cannot be predicted. However, the time when it actually arrived can be read from the time stamp in
the record header,
Section
The software trigger may also be used for time-out function. This is a way to discover faults in the
setup. When the device do not trigger for some reason within a certain time frame, a software com-
mand sequence may be sent and the data can be analyzed to find out what is wrong,
Example 4: A time-out function using software trigger can be implemented like this:
1. Time-out occurs
19-2302 A
2020-09-16
   
,
Figure
11, the
4.4.
Figure
11.
Section

  

parameter can have values in
RECORD_START
ADQ8-4X Manual
19-2302 A 2020-09-16
20(46)
Section
5.9.
Section
5.5.
Section
4.11.
4.4.

RECORD_START
RECORD_START
Example
4.
20(46)

Advertisement

Table of Contents
loading

Table of Contents