American Dynamics SpeedDome Ultra VI Installation And Service Manual page 16

American dynamics speeddome ultra vi security camera: install guide
Hide thumbs Also See for SpeedDome Ultra VI:
Table of Contents

Advertisement

Figure 15. Electrical connections
Pin 1
Pin 1
P7
I/O BOARD
JW1 Terminations
PINS
1-2
2-3
4. Connect alarm output cable, if used,
to P3 connector.
Pin
Color
Designation
1
12Vdc (100mA max.)
2
12Vdc (100mA max.)
3
Output P0 (40mA sync. max.)
4
Output P1 (40mA sync. max.)
5
Output P2 (40mA sync. max.)
6
Output P3 (40mA sync. max.)
7
Ground
8
Ground
SPEEDDOME ULTRA VI
INSTALLATION AND SERVICE GUIDE
Pin 1
P3
P4
P8
Pin 1
P1
JW1
FUNCTION
Unterminated
Terminated
5. Connect alarm input cable, if used,
to P4 connector.
Pin
Color
1
2
3
4
5
6
6. Connect power to P7 connector.
Pin
Color
1
Black
2
Red
3
White
7. Reattach I/O board.
8. Connect power to base.
9. Check LEDs on I/O board to verify power and
data are reaching dome (Figure 16).
a. Observe green (ac power) and yellow
(comm.) LEDs. Green LED glows steadily
and yellow LED glows steadily (RS-422,
Manchester) or blinks (SensorNet).
b. For RS-422, press and hold data test switch
SW1 and observe nearby red and green
LEDs; they indicate the following:
Constant green,
Blinking red
Constant green,
No red
Constant red,
Blinking green
Blinking red,
Green off
Both LEDs off
16
of 34
Designation
Alarm 3 input (3.5mA sink)
Alarm 2 input (3.5mA sink)
Alarm 1 input (3.5mA sink)
Alarm 0 input (3.5mA sink)
Ground
Ground
Designation
24 Vac
Ground
24 Vac
RS-422 line correctly
wired.
RS-422 "Data In -"
shorted to ground.
"Data In +/ -" wires
reversed.
"Data In +" shorted to
ground.
"Data In +/ -" wires
shorted or open.
8000-2830-03, REV. C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras816ls seriesRas816wls series

Table of Contents