4. Set termination jumper JW1 (Figure 12).
Depending upon the dome's location in the
communications line, set jumper JW1 across
the appropriate pins as described in the
following chart:
Position of dome in
communications line...
Between other devices
End of communications line
* Pins 1-2 are closest to 9-pin connector.
Note: You may need a small slotted screwdriver
to gently pry jumper loose. Be careful not to
damage underlying PC board.
Figure 12. Video cable connection and
termination jumper location
Micro
Coax
Cable
SPEEDDOME ULTRA VI
INSTALLATION AND SERVICE GUIDE
Setting
Pins
Unterminated
1-2*
Terminated
2-3
Termination
Jumper JW1
13
of 34
5. Connect the 9-pin plug (data and power) to the
9-pin receptacle (Figure 13).
CAUTION: DO NOT connect 9-pin plug unless
you have performed step 3 first!
a. Feed cables access hole in base.
b. Connect data and power wires to the 9-pin
plug (refer to charts below).
c. Insert plug into mating receptacle in top of
housing and eyeball assembly.
Manchester data and power connections.
Order data cable 88760 (plenum) or 8760
(non-plenum) from Belden by calling
1-800-235-3361.
Pin
Color
1
White
2
Black
3
Black
4
Red
5
White
6-9
RS-422 data and power connections
Pin
Color
1-2
3
Black
4
Red
5
White
6
Orange
7
Green
8
Yellow
9
Brown
SensorNet data and power connections
Pin
Color
1
Orange
2
Yellow
3
Black
4
Red
5
White
6-9
Designation
Manchester (–)
Manchester (+)
24Vac
Ground
24vac
Not used.
Designation
Not used.
24Vac
Ground
24Vac
RS-422 Data In High (+)
RS-422 Data In Low (–)
RS-422 Data Out High (+)
RS-422 Data Out Low (–)
Designation
SensorNet (unshielded)
SensorNet (unshielded)
24Vac
Ground
24Vac
Not used.