Exit Jam; Reversing Jam - Toshiba MR-3011 Service Manual

Reversing automatic document feeder
Table of Contents

Advertisement

(6) Original not reaching exit sensor (1)
• Jam detection for single-sided/duplex originals:
Jam detection is performed after the read motor starts to rotate forward to start scanning the original
waiting at the pre-front side scanning position, until the leading edge of the original has reached the exit
sensor.
• Jam pulse setting
The setting value of an added +30mm to the distance from the pre-scanning position till the exit sensor is
turned ON is set as the jam pulse.
(7) Original not reaching reverse sensor (1)
• Jam detection for duplex originals:
Jam detection is performed after the read motor starts to rotate forward to start scanning the front side of
the original, until the leading edge of the original has reached the reverse sensor.
• Jam pulse setting
The setting value of an added +30mm to the distance from the pre-scanning position till the reverse sensor
is turned ON is set as the jam pulse.

6.3 Exit Jam

(1) Original jamming at exit sensor (1)
• Jam detection for duplex originals:
Jam detection is performed after the trailing edge of original paused at the reverse position has passed the
reverse sensor during the reverse operation, until it has passed the exit sensor.
• Jam pulse setting
The setting value of an added +60mm to the distance from the position where the reverse sensor is turned
OFF till the exit sensor is turned OFF is set as the jam pulse.
(2) Original jamming at exit sensor (2)
• Jam detection for single-sided/duplex originals:
Jam detection is performed after the trailing edge of the original waiting at the pre-front side scanning
position has passed the read sensor during the scanning operation, until it has passed the exit sensor.
• Jam pulse setting
The setting value of an added +60mm to the distance from the position where the read sensor is turned
OFF till the exit sensor is turned OFF is set as the jam pulse.

6.4 Reversing Jam

(1) Original not reaching exit sensor (2)
• Jam detection for duplex originals:
Jam detection is performed after the leading edge of the original paused at the reverse position has
reached the reverse sensor during the reverse discharge operation, until it has reached the exit sensor.
• Jam pulse setting
The setting value of an added +30mm to the distance from the position where the reverse sensor is turned
ON till the exit sensor is turned ON is set as the jam pulse.
(2) Original not reaching reverse sensor (2)
• Jam detection for duplex originals:
Jam detection is performed after reverse motor starts rotating in reverse to start the reverse operation for
the original paused at the reverse position, until the leading edge of the original has reached the reverse
sensor.
• Jam pulse setting
The setting value of an added +30mm to the distance from the pre-reverse position till the reverse sensor
is turned ON is set as the jam pulse.
(3) Original jamming at reverse sensor (1)
• Jam detection for duplex originals:
Jam detection is performed after the trailing edge of the original being scanned has passed the read
sensor, until it has passed the reverse sensor.
• Jam pulse setting
The setting value of an added +30mm to the distance from the position where the read sensor is turned
OFF till the reverse sensor is turned OFF is set as the jam pulse.
October 2000 © TOSHIBA TEC