12.17 Intialization of EEPROM and Adjustment of Sensors
When any of the PC board, original length sensor, and reverse sensor was replaced with new one, initialization
of the EEPROM and adjustment of the sensors must be performed in the adjustment mode (05). Make sure that
there is no original on the sensors and the RADF unit is closed before performing these initialization and
adjustment. See the adjustment mode (05) in the PPC Service Handbook for the details.
Errors such as paper jamming may occur if the EEPROM is not initialized and the sensors are not adjusted after
the above mentioned parts were replaces.
October 2000 © TOSHIBA TEC
12-22