Communication Settings
The communication settings are used to configure the web interface function, detection of
communication errors, and so on.
1. Configure the items.
Item
Communication speed Sets the communication speed between the monitor
Communication Error
Detection
Web Interface
Web Interface Port
AUTH Method
2. Select "Apply".
The setting complete screen is displayed. Select "OK".
1
2
Detail
and network hub.
You can set the following as the message to be
displayed when receipt of image data stops.
Comm. Error Detection On:
Within several seconds after receipt of image data
stops, an alert message in a red box will appear
on the live image screen. When communication
resumes, the alert is cleared and the image is
displayed again.
Comm. Error Detection Off:
When approx. 20 seconds have elapsed after receipt
of image data stops, a communication error message
will appear.
You can operate and configure the monitor from your
web browser over the network.
Sets the port of the web interface.
Sets the authentication method for the web interface. Digest authentication /
100Mbps Half duplex /
100Mbps Full duplex /
1000Mbps Full duplex
On / Off
On / Off
1 to 65535
BASIC authentication