Reading Error Statistics - Omron V600-CA8A-V Series Operation Manual

Parallel interface id controller
Table of Contents

Advertisement

Reading Error Information (ERR)

4-6-2 Reading Error Statistics

Operation Procedure
1, 2, 3...
58
Note Error data (up to 30 items) and error statistics are stored in the ID Controller
RAM. Data storage is supported by a maintenance-free back-up capacitor, and
data is preserved for approximately 20 days (at 25°C) after power to the ID Con-
troller is turned off.
Each time an error occurs, the ID Controller increments the subtotal for the given
type of error. MCBF figures are also calculated simultaneously, and up to 999
data items are stored in the designated memory area. The error statistics read
command enables supervision of error occurrence conditions, and therefore
makes it possible to perform system operation condition diagnosis on a regular
basis.
ERR
RESET
2
INC
Error statistics
display symbol
INC
INC
(Cancel operation by pressing
1. When the ERR Key is pressed, the error menu is shown on the display.
2. When Key 2 is pressed, the error statistics can be read. The first time this
selection is made, the display is used to specify the data (year, month, day)
when statistics collection is about to start.
ERROR1 4
(1)
(Error mode selection menu)
00 00 00
(2)
Year
Month
Day
S
0
10
(3)
Error code
Number of
error occurrences
PARITY E
(4)
S
0 170
(5)
Head no.
COM,DC E
(6)
S
605
)
RESET
Section
4-6

Advertisement