Job Specification (Job) - Omron V600-CA8A-V Series Operation Manual

Parallel interface id controller
Table of Contents

Advertisement

Basic Operations

4-3-2 Job Specification (JOB)

Operation Procedure
1, 2, 3...
44
This enables setting of the Head number and page number for data reading,
writing and testing in the MONITOR Mode.
The following is an example specifying R/W Head 1 and Page 2 (DC memory
area addresses 0200 to 02FF).
(Changing MONITOR Mode)
JOB
*
SET
INC
INC
SET
The JOB Key is effective when the MONITOR Mode initial display is shown.
Press the RESET Key to move from another operation and create the job specifi-
cation.
1. When the JOB Key is pressed, "HEAD1" is displayed. If R/W Head 1 is to be
set, press the SET Key. If R/W Head 2 is to be set, press the INC/DEC Key
once and then press the SET Key.
2. When the Set Key is pressed, "page0" is displayed.
3. Press the INC Key twice and specify page 2.
4. Press the SET Key to set the page number to 2, and then the display
changes to address/data.
Note
1. The Head number is specified using the INC/DEC Key. The numerical keys
are not effective.
2. A page number is the number of a division in the DC memory area (see page
19).
DC memory area
0000
to
Page 0
00FF
0100
to
Page 1
01FF
to
0700
Page 7
to
07FF
MONITOR
HEAD
1
PAGE
00
PAGE
02
a00d00
256 bytes
256 bytes
2048 bytes
256 bytes
Section
4-3
(1)
(2)
(3)
(4)

Advertisement

Table of Contents
loading

This manual is also suitable for:

V600-ca9a-v seriesV600