Using Monitor Unit (V600-P01)

4-1-2 Mounting the Monitor Unit

4-1-3 Nomenclature

Display
Mode Switch
The Monitor Unit is attached by sliding the ID Controller connector cover in the
direction of the arrow on the cover. Press the four tabs on the back of the Monitor
Unit down until they lock to make sure that it is mounted properly and securely.
Note
1. The Monitor Unit can be mounted while power is applied to the ID Controller.
Note, however, that the ID Controller mode when the Monitor Unit is not
mounted is the RUN Mode. This means that when the Monitor Unit mode
switch is set to MONITOR Mode when the Monitor Unit is mounted on the ID
Controller, the ID Controller's mode will change from the RUN Mode to the
MONITOR Mode. Special care must be exercised at this point.
2. If power is applied to the ID Controller with the Monitor Unit attached,
information showing that power is being applied is displayed on the Monitor
Unit display, but this operation has no effect on operation of the device.
3. There are three positions on the mode switch, two of which specify the RUN
Mode. It does not matter which setting is used.
4. When the Monitor Unit is removed, the ID Controller reverts to the RUN
Mode, regardless of which mode it was set in.
Display
All data is displayed here in the MONITOR Mode. In the RUN Mode, only "RUN"
is displayed.
This is used to switch the operation mode of the ID Controller.
Monitor Unit
Connector cover
ID Controller
Mode switch
Section
4-1
Operation
Keys
39