Reading Error Data - Omron V600-CA8A-V Series Operation Manual

Parallel interface id controller
Table of Contents

Advertisement

Reading Error Information (ERR)

4-6-1 Reading Error Data

1, 2, 3...
2. When the ERR Key is pressed, the error mode selection menu appears on
the display. Use numerical keys 1 to 4 to select the error mode.
The ID Controller has a memory area designated for data storage of errors oc-
curring in the RUN Mode. This memory area can store up to 30 items of error
occurrence data, and if this number is exceeded, data is written over the first
item and continues on sequentially. The read command can be used to read
data from the newest items.
ERROR1 4
RESET
ERR
(Error mode selection menu)
NO ERROR
1
NO1RD172
1
Error
occurrence no.
Error data display symbol
NO DC
NO2AR 14
INC
CMD
(Cancel operation by pressing
1. When the ERR Key is pressed, the error menu is shown on the display.
2. When Key 1 is pressed, error data can be read. If there are no errors, NO
ERROR appears on the display. When the RESET Key is pressed, address/
data display is restored.
3. If there are errors, they are read out sequentially from the latest error.
4. While the error code is being displayed, use the horizontal cursor keys to
display the error messages. When one of the horizontal cursor keys is
pressed again, error code display is restored.
5. Press the INC Key to display the errors in order. Press the DEC Key to per-
form the reverse operation.
(1)
(2)
(No errors)
(3)
Error code
Command
name
Head no.
E
(4)
(Error message)
(5)
E
)
RESET
Section
4-6
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

V600-ca9a-v seriesV600

Table of Contents