The Agilent Infiniium Oscilloscope Model 54830 Series at a Glance
Ease of use with high performance
The Agilent Technologies Infiniium oscilloscopes
combine unprecedented ease-of-use with high-
performance digitizing oscilloscope functionality
to simplify your design and analysis measurement
tasks.
Traditional oscilloscope front-panel interface
provides direct access to the controls needed
for most troubleshooting tasks.
Graphical user interface with menus,
windows, dialogs, and toolbars provides easy
access to dozens of configuration and
analysis tools, ensuring you can set up and
make the most complex measurements.
Agilent 54830 offers 2 channels, 4 GSa/s
sampling rate in 1-channel mode, 2 GSa/s
sampling rate in 2-channel mode, 600 MHz
bandwidth. The 54830 MSO also includes 16
digital channels.
Agilent 54831 offers 4 channels, 4 GSa/s
sampling rate in 2-channel mode, 2 GSa/s
sampling rate in 4-channel mode, 600 MHz
bandwidth. The 54831 MSO also includes 16
digital channels.
Agilent 54832 offers 4 channels, 4 GSa/s
sampling rate in 2-channel mode, 2 GSa/s
sampling rate in 4-channel mode, 1 GHz
bandwidth. The 54832 MSO also includes 16
digital channels.
Agilent 54833 offers 2 channels, 4 GSa/s
sampling rate in 1-channel mode, 2 GSa/s
sampling rate in 2-channel mode, 1 GHz
bandwidth. The 54833 MSO also includes 16
digital channels.
Display shows waveforms and graphical user
interface
Graphical interface allows direct interaction
with waveforms, including drag-and-drop
positioning and instant waveform zoom
Waveforms displayed in color, making
correlation easy
Current configuration parameters displayed
near the waveform display and are color-
coded to make identification easy
Graphical interface menus and toolbars
simplify complex measurement setups
Horizontal controls set sweep speed and position
Main sweep speeds from 200 ps/div to 20 s/div
Delayed sweep speeds from 1 ps/div to main
time base setting
Intensified waveforms on main sweep
window make it easy to see what will appear
ii
in delayed sweep window
Acquisition and general controls start and stop
the oscilloscope and do basic setup
Run and stop controls for continuous or
single-shot acquisitions
Clear display before one or more acquisitions
Default setup and Autoscale set initial
configuration
Hard disk drive and floppy disk drive for saving
and restoring setups and measurement results
Store measurement displays for inclusion in
reports and test setup guides
Store oscilloscope setups to repeat tests
another time
Hard disk stores oscilloscope operating
system
Trigger setup controls set mode and basic
parameters
Select Edge, Glitch, or Advanced Modes
Choose input source and slope
Set coupling for trigger
Use graphical user interface to simplify
configuration of pattern, state, delay,
violation, and video triggers
Use auxiliary trigger to increase triggering
flexibility
Vertical controls set input coupling, impedance,
attenuation, and position
AC or DC input coupling
1 MΩ or 50Ω input impedance
Input attenuation adjustable from 2 mV/div to
1 V/div (plus 2 V/div in 1 MΩ)
Color-coded knobs make it easy to find the
controls that affect each waveform
Marker and quick measurements help measure
waveform parameters
Waveform markers A and B to check voltage
and ∆−time at any point on the displayed
waveform
Quick Meas executes up to four predefined
measurements instantly
Service Policy
The service policy of this oscilloscope requires
replacing defective assemblies. Some
assemblies can be replaced on an exchange
basis. Items such as the vertical attenuators,
which are subject to wear and tear based on
frequency of use, are a maintenance item that
may need occasional replacement.