ADTRAN 1200051L1 User Manual page 131

Dual port isdn service unit
Table of Contents

Advertisement

S74.......DTE STOP
S75.......DTE FLOW
S76.......DTE CLOCK
S135.....
The following are the string locations for stored numbers 0 - 9:
SS80.....SN0 LOC
SS81.....SN1 LOC
SS82.....SN2 LOC
SS83.....SN3 LOC
SS84.....SN4 LOC
SS85.....SN5 LOC
SS86.....SN6 LOC
SS87.....SN7 LOC
SS88.....SN8 LOC
SS89.....SN9 LOC
S118 = 0
S118 =32
61200051L1-1D
Selects the number of asynchronous stop bits. More
than one option can be set at the same time.
0 = 1 stop bit (default)
1 = 1.5 stop bits
2 = 2 stop bits
Selects asynchronous flow control
0 = None (default)
1 = Hardware flow. CTS from DCE controls DTE.
2 = Hardware flow. RTS from DTE controls DCE.
3 = Hardware flow. RTS and CTS flow control.
4 = Software flow. XON/XOFF from DCE controls
DTE.
8 = Software flow. XON/XOFF from DTE controls
DCE.
12 = Software flow. XON/XOFF controls DTE and
DCE.
Selects DTE connector transmit clock timing source.
0 = Internal (ISU 2x64 supplies timing) (default)
1 = External (DTE supplies timing)
Value determines whether or not the ISDN switch
should consider a DTE port busy. S23 must be pro-
grammed before this register is used.
0 = DTE port is not busy (default)
1 = DTE port is busy
Stored number 0 string
Stored number 1 string
Stored number 2 string
Stored number 3 string
Stored number 4 string
Stored number 5 string
Stored number 6 string
Stored number 7 string
Stored number 8 string
Stored number 9 string
CHAP Authentication (default)
PAP Authentication (required for MP connection with
WIN 95)
ISU 2x64 Dual Port ISDN Service Unit User Manual
Appendix D: S-Register List
117

Advertisement

Table of Contents
loading

This manual is also suitable for:

1200051l21200051l51200051l661200051l1Isu 2x64

Table of Contents