Table 3. Humidity Control Modes of Operations
Function
Setting Mode
Normal
Max
Humidification
Only
humidification set−point
15%
Normal
Dehumidification
Only
Max
Climate IQ (Auto)
Dehumidification
Only
The below adjustment tools are only available with either Max or Climate
IQ setting selected.
overcooling
0°F
0°F
Description
These thermostat modes allow the homeowner
to control the relative humidity (RH) between
15% and 45%. The following conditions must be
met for either mode to operate:
Humidification mode has been enabled
Unit is in HEAT mode
Humidification demand exists
Additionally, the NORMAL mode requires that
heat demand exists.
40%
Both Staged and Modulating Outdoor Units: This
setting is recommended when the air outside is
not too humid.
• Staged
Outdoor
Unit:
This
recommended when the outdoor air is
excessively humid. This setting may cool your
home below the set temperature in order to
remove excessive indoor humidity.
• Modulating Outdoor Unit: Recommend when
the outdoor air is excessively humid. This
setting adjusts cooling based on duct sensor
data. This setting may cool your home below
the set temperature.
NOTE:
Discharge air temperature sensor
(catalog number 88K38) is required.
Climate IQ (Auto) is applicable only to iComfort
S30 controlled system with either communicating
staged or modulating outdoor units only. This
setting automatically adjusts both indoor fan
speed and cooling power based on local climate
conditions using Climate IQ
technology. This
®
setting may cool your home below the set
temperature.
2°F
Table 3. Humidity Control Modes of Operations
Function
Dehumidification
Only
Humidification +
Dehumidification
45%
Dew Point
setting
is
Variable capacity outdoor units are XC20, XP20, XC25 and XP25
1
When either an auxiliary dehumidifier or Humiditrol is installed the only setting
available is dehumidification set point slider adjustment tool is available. The
only adjustment tool will be the Dehumidification Set Point Percentage.
Humiditrol: When Humiditrol accessory is used there are an additional
parameter settings that your installer can adjust. This setting option is available
under the Dealer Control Center on the thermostat. The setting is called
Humiditrol Comfort Adjust, and the settings options are:
• Maximum Overcooling
• Midpoint Overcooling
• Minimum Overcooling
The factory default for this setting is Maximum Overcooling. Please refer to
the documentation included with the Humiditrol accessory for further details.
4°F
14
Setting Mode
Description
dehumidification set−point
48%
40%
humidification set−point + dehumification set−point
40%
15%
Dew point adjustment mode will change the humidification set point based
on the outdoor temperature and a user-defined dew point adjustment
setting.
NOTE:
Dew Point - Adjustment requires an outdoor temperature sensor
and is automatically controlled by the outside temperature.
dew point
0%
−15%
Dehumidification Accessory Installed
60%
48%
60%
on
15%