Triple Surface Unit: Right Front(Rf) Element - LG LUTE4619SN Service Manual

Slide-in electric range
Hide thumbs Also See for LUTE4619SN:
Table of Contents

Advertisement

Components
1. Refer to page 3-8 for the servicing procedure
Triple surface unit:
Right Front(RF) Element
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the (E1 & 1A) and (E2 & 1A)
5. Touch the ohmmeter test leads to limiter terminals 1A and 2A.
Test procedures
and (E3 & 1A)
The meter should indicate.
- (E3 & 1A) M 70.5 Ω ± 10%
- (E2 & 1A) M 50.0 Ω ± 10%
- (E1 & 1A) M 49.5 Ω ± 10%
The meter should indicate continuity(0Ω)
Normal: Approximately 67 Ω
Normal: Approximately 48.5 Ω
Normal: Approximately 50 Ω
Normal: continuity
(below 0.5 Ω)
If not replace
4-14
Results

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents