COMPONENTS
Single surface units:
1. Refer to page 3-6 for the servicing procedure
Left Rear(LR)
2. Set the Multiple meter scale to the R x 1
Right Rear(RR)
3. Disconnect wires from cook-top elements
Element
4. Touch the ohmmeter test leads to the element terminal and 1A.
5. Touch the ohmmeter test leads to limiter terminals 1B and 2B.
TEST PROCEDURE
The meter should indicate 46 Ω ± 10%
2A
With the temperature below 150˚F, the meter should indicate an
open circuit(infinite).
With the temperature above 150˚F, the meter should indicate
continuity (0Ω).
1B
2B
1A
-4-4-
RESULTS
Normal: Approximately 46 Ω,
If not replace
Element
Element
terminal
terminal
Element
Element
terminal
terminal
Below 150˚F
M open circuit(infinite).
Above 150˚F
M continuity (0 Ω)