Components
Triple surface unit :
Right Front (RF)
Element
Test procedures
1. Refer to page 3-4 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the (1 & 2A)
and (4 & 2A) and (3 & 2A) the meter should
indicate :
- (1 & 2A) 52 Ω ± 10%
- (4 & 2A) 49 Ω ± 10%
- (3 & 2A) 68 Ω ± 10%
1
2A
5. Touch the ohmmeter test leads to limiter terminal
1B and 2B. With the temperature below 150℉, the
meter should indicate an open circuit (infinite)
With the temperature above 150℉, the meter
should indicate continuity (0 Ω)
1B
2B
3
4
4-7
Results
Normal : Approximately 52 Ω
Normal : Approximately 49 Ω
Normal : Approximately 68 Ω
Below 150˚F
open circuit(infinite).
Above 150˚F
continuity (0 Ω)