Components
1. Refer to page 3-8 for the servicing procedure
Center Rear(CR) Element
: Warming Zone (Plane
2. Set the Multiple meter scale to the R x 1
Heater)
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the element terminal E1 and
5. Touch the ohmmeter test leads to limiter terminals 1A and 2A
Test procedures
E2.
The meter should indicate 570Ω ± 10%
1A
2A
1E
2E
With the temperature below 150˚F, the meter should indicate an
open circuit(infinite).
With the temperature above 150˚F, the meter should indicate
continuity (0Ω).
1A
2A
1E
2E
Normal: Approximately 570 Ω,
If not replace
Below 150˚F
M open circuit(infinite).
Above 150˚F
M continuity (0 Ω)
4-12