Components
Upper oven Bake heater
1. Remove wire leads
2. Measure resistance after cooling down
Lower oven Broil heater
1. Remove wire leads
2. Measure resistance after cooling down
Lower oven Conv. heater
1. Remove wire leads
2. Measure resistance after cooling down
Test procedures
4-4
Results
Normal : Approximately 24 Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was tested at room temperature
(77˚F/25˚C)
Be careful the element is sensitive to temperature.
Normal : Approximately 14.7 Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was tested at room temperature
(77˚F/25˚C)
Be careful the element is sensitive to temperature.
Normal : Approximately 24 Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was tested at room temperature
(77˚F/25˚C)
Be careful the element is sensitive to temperature.