Single Surface Units: Left Rear (Lr) And Right Rear(Rr) Element - LG LUTE4619SN Service Manual

Slide-in electric range
Hide thumbs Also See for LUTE4619SN:
Table of Contents

Advertisement

Components
1. Refer to page 3-8 for the servicing procedure
Single surface units:
Left Rear (LR) and
2. Set the Multiple meter scale to the R x 1
Right Rear(RR) Element
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the element terminal and 1A.
5. Touch the ohmmeter test leads to limiter terminals 1B and 2B.
terminal
terminal
Test procedures
The meter should indicate 46 Ω ± 10%
Element
Element
terminal
terminal
1A
With the temperature below 150˚F, the meter should indicate an
open circuit(infinite).
With the temperature above 150˚F, the meter should indicate
continuity (0Ω).
1B
2B
Normal: Approximately 46 Ω,
If not replace
Below 150˚F
M open circuit(infinite).
Above 150˚F
M continuity (0 Ω)
4-11
Results

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents