General Information

1. Always use a digital multi-meter for electrical testing procedures and record voltage reading results.
2. Before performing any electrical troubleshooting, always:
-Verify proper battery voltage (above 12.4 volts): Batteries reading 12.4 volts or less are considered discharged
-Check that all engine and chassis ground wires are securely connected and not damaged.
3. Use of test lights and continuity testers may result in false readings and lead to an incorrect diagnosis.
4. Occasionally, electrical testing requires the use of a jumper wire to bypass a safety interlock switch, allowing
the technician to continue troubleshooting by taking the switch out of the circuit.
NOTE: Jumper wires should be used for troubleshooting only, NEVER leave a jumper wire in place to
bypass a safety circuit.
Z Master 7500-D Series Service Manual
March 2018 - Digital Edition
ELECTRICAL
WARNING
Never touch electrical wires or components while the
engine is running. They can be sources of electrical
shocks. Always use test equipment as directed by the
manufacturer.
WARNING
When disconnecting the cable from the battery, start
with the negative terminal first. When connecting the
cable to the battery, start with the positive terminal
first.
WARNING
When removing or installing the battery, do not allow
the battery terminals to touch any metal parts of the
machine. Do not allow metal tools to short between the
battery terminals and metal parts of the machine.