4e - Shower turning off too soon:
1. Check to see if you have 'Warm Up' mode enabled. This is designed to 'pause'
the shower once showering temperature is reached.
2. Check to see if you have a maximum showering duration set. This is designed to
turn off the shower after a pre-determined duration.
3. Check to see if you are using pre-defined showering experiences. These may turn
off the shower after a pre-determined duration.
4. The shower is designed to turn off after 30 minutes.
5. Use the Mira Showers app to check the error log. The shower is designed to turn
off if the outlet temperature is too high.
6. Check inlet water temperature and pressures are within specification. The shower
may turn off if these are out of specification. Tip: Use the Mira Showers app to check
the temperature of the hot water inlet.
7. If none of the above resolved the issue, contact Mira Customer Service Team.
4f - Noise:
1. Pumped digital mixing valves can get air locked if not installed in accordance with
the instructions in this guide and may exhibit outlet flow fluctuations and a high pitch
"squealing" noise. Ensure the plumbing system eliminates air locking.
2. Some plumbing systems can produce "water hammer". To reduce this effect,
ensure all pipework is securely fixed.
3. The type of wall or flooring the appliance is fixed to will affect the perceived noise
level from the product. For a quieter operation install the product to solid walls or
structures.
4. If none of the above resolved the issue, contact Mira Customer Service Team.