User Maintenance

WARNING! PLEASE OBSERVE THE FOLLOWING TO REDUCE
THE RISK OF INJURY OR PRODUCT DAMAGE:
■ DO NOT allow children to clean or perform any user maintenance
to the shower unit without supervision.
■ If the shower is not to be used for a long period, the water
supply to the shower unit should be isolated. If the shower unit
or pipework is at risk of freezing during this period, a qualified,
competent person should drain them of water.

Filter Cleaning

1
Isolate the water supplies and turn the
shower on to relieve the water pressure.
Turn the shower off.
3
Pull the stop assembly from the body, then
unscrew and remove the large brass nut
from the body.
1285246-W2-D
Caution! Take care
not to damage the
chrome surfaces.
Stop
Assembly
2
Pull the control lever from the body then
remove the retaining screw with a 2.5 mm
hex key.
4
Ensuring correct orientation, "OFF" at
the top, refit the stop assembly and the
retaining screw to the body.