Advertisement

Mira Agile S Eco, Mira Agile S, Mira Agile ERD+
Mira Agile Sense ERD+, Mira Agile Store EV+, Mira Agile EV+
Installation and User Guide
These instructions must be left with the user
1
For SPARES,
ADVICE or REPAIRS
please call us free
on 0800 001 4040
(UK only)
1285246-W2-D

Advertisement

Table of Contents
loading

Summary of Contents for Mira Agile S B97C

  • Page 1 Mira Agile S Eco, Mira Agile S, Mira Agile ERD+ Mira Agile Sense ERD+, Mira Agile Store EV+, Mira Agile EV+ For SPARES, ADVICE or REPAIRS please call us free on 0800 001 4040 (UK only) Installation and User Guide...
  • Page 2: Type 2 Valves

    Introduction Thank you for choosing a Mira shower. To enjoy the full potential of your new shower, please take time to read this guide thoroughly, and keep it handy for future reference. Products manufactured by Kohler Mira Ltd are designed to be safe, provided that they are installed, used and maintained in good working order, in accordance with our instructions and recommendations.
  • Page 3: Pack Contents

    Design Registration & Patents Design Registration: 001312649-0001 to 001312649-0022 Patents: 2 422 886, 2 491 044, 2 500 948, 2 544 770 Euro: 1 672 257, 2 710 194, DE, FR, GB, IT, NL, SE USA: 8 167 215, 8 517 282 Pack Contents Agile S Agile S Eco...
  • Page 4 Pack Contents Agile ERD+ Agile Sense ERD+ Agile Store EV+ 1 x Shower Unit 1 x Wallplate Pack 1 x First Fix Pipe Guide 1 x Component Pack (2 x Screws, 2 x Wall Plugs, 2 x Hex Key, 1 x Grease Sachet, 2 x Grubscrew - 1 as a spare) Documents 1 x Installation &...
  • Page 5: Important Safety Information

    Ensure that any pipework that could become frozen is properly insulated. 3. DO NOT perform any unspecified modifications to the shower or its accessories. When servicing only use genuine Kohler Mira replacement parts. 4. If the shower is dismantled during installation or servicing then, upon completion, an inspection must be made to ensure all connections are tight and that there are no leaks.
  • Page 6 13. DO NOT switch the shower off and back on while standing in the water flow. 14. DO NOT fit any form of outlet flow control. Only Mira recommended outlet fittings should be used. 15. The showerhead must be descaled regularly. Any blockage of the showerhead or hose may affect showering performance.
  • Page 7: Specifications

    Specifications For Type 2 Valves, the supply conditions specified in the TMV2 Requirements Manual take precedence over the operating parameters which follow. Pressures • Max Static Pressure: 10 Bar. • Max Maintained Pressure: 5 Bar. • Min Maintained Pressure (Gravity System): 0.1 Bar (0.5 Bar for models with Eco Showerhead).
  • Page 8: Installation

    Unvented Mains Pressure System: The thermostatic mixer can be installed with an unvented, stored hot water system. Pumped System: The thermostatic mixer can be installed with an inlet pump (twin impeller). The pump must be installed in a suitable location and in accordance with its instructions. Installation General 1.
  • Page 9: Tools Required

    12. The position of the shower and shower fittings must provide a minimum air gap of 25  m m between the showerhead and the spill over level of any bath, shower tray or basin. There must be a minimum distance of 30  m m between the showerhead and the spill over lever of any toilet, bidet or other appliance with a Fluid Category 5 backflow risk.
  • Page 10 Installation Shower Positioning The shower fittings should be positioned at a convenient height for all the family. Position the fittings to spray across rather then towards the opening of the cubicle and also away from the shower control. Avoid layouts where the shower hose will be sharply kinked.
  • Page 11 1. Pipework must be at 50 mm centres, level fig 1 Make sure that and perpendicular to the finished wall the pipework is level surface (see fig 1). 2. It is recommended that the pipework is secure but not rigidly fixed at this stage, in case of further adjustment when the retaining wallplate is fitted.
  • Page 12 7. For Stud Partition Walls First Fix Pipe Guide Mark these two Holes a. For stud partition wall installations make sure that a wooden noggin is in place directly behind the final valve position. The supplied First Fix Pipe Guide MUST be used to mark the pipework centres, check that the pipe guide is level and mark the pipework centres.
  • Page 13 LEVEL LEVEL * Pipework that is not level will make final assembly of the valve very difficult d. Once the pipework is in place, slide the First Fix Pipe Guide over the protruding pipework. Important! At this stage re-check the pipework is square and level*. Mark and drill the pipe guide fixing holes then attach directly to the noggin.
  • Page 14 Drill holes here Pipe Shroud Seal the pipework where it comes through the wall 6 mm Wall Plug For solid wall installations, fit the supplied Fit the Pipe Shroud over the pipe stubs. Use wall plugs (alternative fixings can be used the two holes in the pipe shroud as a template - countersunk head only) to allow fixing of and drill through them into the finished wall...
  • Page 15 Pipe Retaining Screw Screws Pipe Hex Key Shroud Integrated Spirit Level To prevent the possibility of property water Ensure the pipes do not damage the screws MUST be tightened push back into the wall. Loosen the screws and remove the spirit YOU MUST FULLY TIGHTEN the pipe level and refit the pipe shroud to ensure the retaining screws to clamp the pipes.
  • Page 16 Orientation markers always on top Retaining Screw Backplate To prevent the possibility of property damage / personal injury the retaining screw MUST be tightened. Flush the water supplies thoroughly DO NOT USE POWER TOOLS TO TIGHTEN before connecting the shower unit. THE RETAINING SCREW In retrofit installations (where you are Grease the pipes and push the backplate fully...
  • Page 17 Turn on the water supplies and check for leaks. Refer to separate guide for instructions on how to fit the shower fittings. Note: The shower must be commissioned before first use, see section ‘Commissioning’ and ‘Information on Flow Regulators’. 1285246-W2-D...
  • Page 18 Note: In some circumstances such as when the incoming cold water temperature supply is very low to a combination boiler a 9 l/min flow regulator may be required to improve the hot water performance. Contact Mira Customer Service. Note: The 6 l/min flow regulator may affect the performance of some combination boilers while the shower is running.
  • Page 19 Commissioning Before using the shower, the maximum temperature must be checked to make sure that it is at a safe level. It has been preset to a safe showering temperature under ideal conditions at the factory, appropriate for most systems. However, site conditions and personal preference may make it necessary to reset this temperature.
  • Page 20 Red Stopper Handle Drive Cooler Warmer Lift and adjust the position of the red stopper on back of the handle drive. Each serration will adjust the temperature approximately 1° C + = Warmer - = Cooler Ensuring correct orientation, “OFF” at the top, refit the stop assembly and the Turn the shower off again.
  • Page 21: Operation

    Operation Please read “Important Safety Information” of this guide before using the shower for the first time. Single Control mixers use a single sequential control for on / off and temperature control. The control operates clockwise in the following sequence: •...
  • Page 22: User Maintenance

    User Maintenance WARNING! PLEASE OBSERVE THE FOLLOWING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE: ■ DO NOT allow children to clean or perform any user maintenance to the shower unit without supervision. ■ If the shower is not to be used for a long period, the water supply to the shower unit should be isolated.
  • Page 23 Grip the stop assembly and withdraw the Rinse the cartridge in clean warm water, cartridge from the body. removing any dirt or debris. END VIEW Reassemble the valve in reverse order. Restore the water supplies and check for leaks. Note: Make sure that the cartridge locates correctly. Cleaning Many household cleaners contain abrasives and chemical substances, and should not be used for cleaning plated or plastic fittings.
  • Page 24: Fault Diagnosis

    Fault Diagnosis Only use genuine Kohler Mira replacement parts. If you require a Mira trained service engineer or agent, please see “Customer Service” on the back cover of this guide. Symptom Cause Recommended Action Only hot or cold water Water inlets are reversed Installation error, supply pipework from the shower.
  • Page 25: Spare Parts

    Spare Parts Agile S Agile S Eco Agile EV+ 1736.980 Backplate 1736.984 1736.950 Headnut Cartridge Assembly 1736.949 Control Assembly 1736.962 1736.706 Wall Plate 1736.990 Outlet Nipple Assembly Pipe Guide 1736.951 Component Pack 1736.986 Screw Pack - A 1285246-W2-D...
  • Page 26 Spare Parts Agile ERD+ Agile Sense ERD+ Agile Store EV+ 1736.980 Backplate 1736.984 1736.950 Headnut Cartridge Assembly 1736.949 Control Assembly 1736.962 1736.990 Wall Plate Pipe Guide Assembly 1928.049 Component Pack 1736.986 Screw Pack - A 1285246-W2-D...
  • Page 27 Notes 1285246-W2-D...
  • Page 28: Customer Service

    ● Servicing must only be undertaken by us or our Spares and Accessories appointed representative. We hold the largest stocks of genuine Mira Note! If a service visit is required the product must spares and accessories.Contact us for a be fully installed and connected to services.
  • Page 29: Product Data Sheet

    Replaceable cartridge For your customer Single control for flow and temperature Mira Magni-flo™ technology delivers up to 3x more flow, even at low pressure 90 mm showerhead with rub-clean nozzles for a greater showering experience (Agile EV+ has 4 spray 110 mm showerhead)
  • Page 30: Product Specification

    Product Specification Technical Details Temperature control Performance Flow rate (at handset): Agile S EV, 10 l/min at 0.5 bar; Control type: Thermostatic temperature control Agile S Eco EV, 6 l/min at 0.5 bar; Agile EV+, 11 l/min at 0.5 bar Installation Temperature stability: ±...
  • Page 31 This guarantee is in addition to your statutory outlet pipe work if the shower fittings are 0800 001 4040 Thank you for purchasing a quality Mira product. To rights and is subject to the following conditions : installed in conjunction with a product that enjoy the full potential of your new product, please ●...

This manual is also suitable for:

Agile s eco b97cAgile store ev+ b97dAgile ev+ b97cAgile erd+ b97dAgile sense erd+ b97d

Table of Contents