Key Functions In Measurement Mode - Siemens SITRANS LR560 Operating Instructions Manual

Radar transmitters (foundation fieldbus)
Hide thumbs Also See for SITRANS LR560:
Table of Contents

Advertisement

Commissioning
6.5 Commissioning via handheld programmer
6.5.4

Key functions in measurement mode

Key functions in measurement mode
Key
48
Function
Result
Updates the loop
New value is shown in secondary region of local display.
current
Updates internal
enclosure tempera-
ture reading
Updates echo confi-
New value is shown in secondary region of local display.
dence value
Updates distance
measurement
Mode opens
Opens the menu level last displayed in this power cycle, unless
PROGRAM mode
power has been cycled since exiting PROGRAM mode or more
than 10 minutes have elapsed since PROGRAM mode was used.
Then top level menu will be displayed.
Home toggles local
Local display toggles between % or linear units
display
RIGHT arrow opens
Opens the top level menu.
PROGRAM mode
UP or DOWN arrow
Local display shows measured value in either linear units or per-
toggles between
cent.
linear units and per-
cent
LR560 (FOUNDATION FIELDBUS)