Power Saving Delay
•
Sets the amount of time before initiating the standby state specified in Power Saving
Mode when no signal is present
•
Options: 1 Minute, 5 Minutes, 15 Minutes, 30 Minutes, 60 Minutes; Default: 5 Minutes
Power On Delay
•
Sets the amount of time to delay between an ON command being received and the display
leaving standby. This can be useful when multiple displays are on the same electrical
circuit, and it is beneficial to avoid all displays leaving standby simultaneously, causing a
large inrush of current.
•
Options: 0-10 seconds, in 0.1 second increments; Default: 0 seconds
Power Down Mode
•
Set the action to take when the display enters standby
•
Options: Standby Mode, Networked Standby Mode, Fast Start; Default: Standby Mode
•
Standby Mode: The lowest power standby setting. CEC, LAN, DB9 RS232, and USB
communication are disabled. IR, Keypad connector will remain active.
•
Note: To remove display from standby with the IR remote or keypad, IR Remote Lock or
Keypad Lock must be disabled.
•
Networked Standby Mode: The display will enter a low power standby state with LAN,
DB9 RS232, USB and IR communications active.
•
Fast Start: The display will enter a standby state with partially reduced power, allowing for
3-5 second wait between an ON command being sent, and image being displayed. IR,
Keypad, CEC, LAN, DB9 RS232, and USB communication will remain active.
OPS Power Down Check
•
When enabled, the system will wait for an indication from the OPS module that it has
finished its power down sequence, before going into the standby state specified in Power
Down Mode
•
Options: Disable, Enable; Default: Enable