Control Panel
Where can I find free documentation and on-line support for this product?
Go to www.boschsecurity.us.
What is the default passcode to enter into the web browser for the B426 Ethernet
Communication Module?
The correct default passcode is: B42V2.
How do I add a RADION keyfob or an EN1224-ON keyfob to a user?
You can add a RADION keyfob or an Inovonics transmitter to a new or existing user using a
B920/B930 keypad from within Keyfob menu of the Add User or Edit User menu.
How do I add or remove an RF Point from the B820 SDI2 Inovonics Interface Module?
At a B920/B930 keypad, enter your Installer passcode, and then go to the Installer > Wireless
> Points menu.
How do I add or remove an RF point from the B810?
At a B920/B930 keypad, enter your Installer passcode, and then go to the Installer > Wireless
> Points menu.
Why does the system turn Part On with a delay when I try turn the system All On?
All On means to turn the system All On with delay. If you do not leave the area, the system
turns Part On.
Why is Comm Trouble showing in the history log after most of my reports or Central Station
is receiving a BT01 signal, but the panel is reporting correctly, but how do I turn it off?
Comm trouble is declared when the panel tried 2 attempts and did not reach the Central
Station.
What does the Comm RT Fail mean?
Comm RT Fail is the panel tried all 10 attempts and was unsuccessful in sending the report to
the Central Station.
Why does the D9210C say "Not Ready?"
Thr Access Door point is not programmed. Program the Access Door Point.
What is the difference between a Comm Fail and a Phone Line Fail error message?
Comm Fail occurs when the control panel tries to reach the Central Station on ten
unsuccessful occurrences to report without success. Phone Fail occurs when the phone line
has no voltage on it.
What is, and how do I clear the 24 Bypass from the keypad?
A 24 Bypass error occurs when a 24 hour point is bypassed. In order to clear it, a point needs
to be normal to unbypass the point.
What is SDI XX Comm Trouble?
This error occurs when you have a SDI communication device that is no longer communicating
with the Central Station.
Bosch Security Systems, Inc.
Quick Reference Guide
Frequently Asked Questions | en
2014.05 | 05 | F.01U.265.463
41