The Point Response Selections table indicate:
To make a custom point index, use the Point Type Selection table and Point Response Selections
table. For example, to create an inferior Follower point with a delay on Open and Trouble on
Short, use Point Type 3 and Point Response 5.
Point Response
Selection*
Turned on
(armed)
Turned off
(disarmed)
24-Hour
*Selections: D = Delayed Response, I = Instant Alarm, S = Supervisory, T = Trouble, B = No
Response
Table 7.5: Point Response Selections*
Bosch Security Systems, Inc.
D = Delayed Response
I = Instant Alarm
S = Supervisory
T = Trouble
Blank = No Response
0 1
Open
I
I
Short
I
I
Open
T
Short
Open
I
T
Short
I
I
Quick Reference Guide
2
3
4
5
6
7
I
I
D
D
I
I
I
I
I
D
T
T
T
T
I
T
I
T
T
I
T
Setting Up Points and Outputs | en
8
9
A
B
C
I
D
I
I
I
D
D
I
I
I
T
I
I
T
I
T
I
T
S
T
S
T
S
S
2014.05 | 05 | F.01U.265.463
19
D
E
F
I
I
T
I
I
I
I
T
I
S
N/A
S