Local Configuration Of The Keystone Epi2; Keystone Epi2 Default General Configuration - Emerson Keystone EPI2 63 Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Installation, Operation and Maintenance Manual
MAN-10-04-100-0711-EN Rev. 0
6.2

Local Configuration of the Keystone EPI2

WARNING
!
The configuration must be done while the actuator is powered on. As a consequence,
all configuration operations must be carried out by specifically qualified personnel for
operations on powered electronic cards.
6.2.1

Keystone EPI2 Default General Configuration

NOTE
The actuators are set in the workshop with the following configuration (default value):
If the application requires different actuator configurations, please proceed as described
in this chapter.
NOTE
Please note that the actuator configuration does not need to be done in succession as
indicated in the following pages. Each parameter can be set independently.
The configuration of the actuator parameters is done through the following tools:
Actuator Configuration
CL limit switch by position
OP limit switch by position
Stroking time in CL (6): 28 s for models 063/125/250/500, 45 s for model 1000 and
100 s for model 2000
Stroking time in OP (6): 28 s for models 063/125/250/500, 45 s for model 1000 and
100 s for model 2000
Torque limiting device in CL set at about 100% of nominal torque
Torque limiting device in OP set at about 100% of nominal torque
Reverse mode off
Monitor Relay NC (in normal condition, i.e. without alarms)
Blinker / Local Selector relay off (always Open)
Two rotary selector switches SW6 and SW4 for actuator configuration
Enter pushbutton SW5 (confirmation pushbutton)
Dip switch SW3 (enable configuration function)
Green LED indicating power ON (switched on when power supply is available)
Red LED for Enter confirmation (ON onceconfiguration is confirmed)
Mechanical stops
Section 6: Actuator Configuration
October 2020
29