Siemens SIMATIC S7-400H System Manual page 416

Fault-tolerant systems
Hide thumbs Also See for SIMATIC S7-400H:
Table of Contents

Advertisement

Technical data
20.3 Technical specifications of the CPU 416–5H PN/DP; (6ES7 416-5HK06–0AB0)
PNO ID (hexadecimal)
Number of integrated PROFINET IO controllers
Number of PROFINET IO devices that can be
connected
Number of connectable IO devices for RT
of which are in line
Shared Device, supported
Address range
Number of submodules
Maximum user data length, including user data
qualifiers
Maximum user data consistency, including user
data qualifiers
Send clock cycles
Update Time
S7 protocol functions
IRT (Isochronous Real Time)
Prioritized startup
Accelerated (ASU) and Fast Startup Mode (FSU)
Tool change
Changing an IO device without Micro Memory
Card or PG
Designation of the interfaces
Type of interface
Usable interface module
Length of the synchronization cable
416
PG functions
OP functions
PROFINET IO
Vendor ID: 0x002A
Device ID: 0x0102
1
256
256
256
No
Maximum 8 KB inputs/outputs
Maximum 8192
Mixed modules count twice
1440 bytes
1024 bytes
250 µs, 500 µs, 1 ms, 2 ms, 4 ms
250 μs, 0.5 ms, 1 ms, 2 ms, 4 ms, 8 ms, 16 ms,
32 ms, 64 ms, 128 ms, 256 ms, and 512 ms
The minimum value depends on the
communication slice set for PROFINET IO, the
number of IO devices, and the amount of
configured user data.
Yes
Yes
No
No
No
Yes
4th and 5th interface
IF1, IF2
Plug-in synchronization module (FOC)
Synchronization module IF 960 (only in
redundant mode; in stand-alone mode the
interface remains free/covered)
Maximum 10 km
System Manual, 03/2012, A5E00267695-11