15F144 Hose Wire Jumper - Graco Power-Lock Instructions - Parts Manual

Heated hose
Table of Contents

Advertisement

15F144 Hose Wire Jumper

Use the 15F144 Hose Wire Jumper to heat
only the major volume hose, in a wide ratio
system.
To build one complete 50 ft single side heated
hose bundle, order the following parts:
Ref.
Part
Description
100
15F144
JUMPER, hose wire; includes
two 117789 electrical connec-
tors; 50 ft (15.2 m) long
101
chart 2,
HOSE, resin, heated; 50 ft
page 19
(15.2 m) minimum
102
15B296 CABLE, FTS
103
15C517 HARNESS, hose jumper
104
261670
FLUID TEMPERATURE
SENSOR; see page 18
105
purchase
HOSE, hardener, unheated; 50
locally
ft (15.2 m) minimum; customer
supplied
106
purchase
CONNECTORS, fluid; as
locally
required to complete assem-
bly; not shown
20
Install as follows:
WARNING
Read warnings, pages 6 and 7.
Hoses (101 and 105) must be sized and
pressure rated to meet the requirements of
Qty
your system.
1
Do not operate heated hose (101) at more
1
than 45 A. If hose is cold, turn current adjust-
ment fully counterclockwise before reheating
1
hose.
1
1
Spray gun must be grounded.
1
1. Wrap hose wire jumper (100) around resin
as
hose (101) in a spiral fashion.
req'd
2. Connect resin hose wire (101a) to other
side of Power-Lock connector (100a); see
page 9.
3. Wrap FTS cable (102) around resin hose
(101) in a spiral fashion.
4. Twist hoses (101 and 105) together to pro-
vide strain relief.
5. Repeat steps 1-4 for each length of hose
(101). Connect hoses, electrical connec-
tors, and cables; see Connect Heated
Hoses, page 9.
6. Install one Power-Lock connector (100a)
between wires; see page 9.
Parts
309572M

Advertisement

Table of Contents
loading

Table of Contents