e. Re-torque all four setscrews to 60 in-lbs
(6.78 N•m).
When torqued to 60 in-lbs (6.78 N•m)
setscrews will be approximately flush
with connector. See F
f. Insert cap plugs over setscrews. See
F
. 9.
IG
Setscrews
F
. 9
IG
g. Wrap connector and wire on each side
of connector in black electrical tape to
help seal out moisture. Ensure 1 in.
(25.4 mm) of wire on each side of con-
nector is wrapped.
309572M
. 9.
IG
Cap plugs
TI9771A
6. Connect cables (F). Slide insulator sleeves
over connection. Leave slack (G) in cables
as stress relief to prevent cable failure.
G
F
. 10
IG
7. Repeat for additional hoses.
8. See Connect 261669 FTS and Heated
Dual Whip Hose, page 12, or Connect