Connect 261670 FTS

CAUTION
Do not coil hose tighter than the minimum
bend radius of 3 ft (0.9 m). Do not subject
hose to excessive weight, impact, or other
abuse.
1. Carefully extend FTS probe (H) into the
hose section from the proportioner. Do not
bend or kink probe. Insert probe in major
volume (resin) side on systems which
are not 1:1 mix ratio.
2. Connect FTS (J) to mix manifold.
S
G
To
Proportioner
309572M
S
R
F
3. Connect fluid hoses to FTS (J).
To use 1/2 in. (13 mm) ID fluid hoses,
remove the adapters from the propor-
tioner fluid manifold and install them in
the FTS swivel inlets.
4. Connect electrical connectors (D). Install
one Power-Lock splice between wires.
Refer to page 9 for instructions.
5. Connect hose assembly cable (F) to FTS
cable (R). Slide insulator sleeves (S) over
connection. Leave slack (G) in cables as
stress relief, to prevent cable failure.
6. See Check Hoses for Leaks, page 14.