How To Fold Ribbon Cable To The Head - Roland VersaCamm VS-640i Service Notes

Hide thumbs Also See for VersaCamm VS-640i:
Table of Contents

Advertisement

3-21 HOW TO FOLD RIBBON CABLE TO THE HEAD

These procedures are for the ribbon cables to the Head. The ribbon
cable and the procedure are different from each connector. Refer to
the following list and procedures and fold the ribbon cables.
Connector A : 1000006702 CABLE-CARD,29P1 256L BB HIGH-V
Connector B : 1000006702 CABLE-CARD,29P1 256L BB HIGH-V
Connector C : 1000006703 CABLE-CARD,29P1 276L BBR HIGH-V
<Connector A : 1000006702 CABLE-CARD,29P1 256L BB HIGH-V>
<Connector A : 1000006702 CABLE-CARD,29P1 256L BB HIGH-V>
Place the ribbon cable whose character side faces up.
1
There is no difference between left and right direc-
tion.
Fold the ribbon cable with 90 degree at the 18 +/-3 mm point
2
from the left end.
Fold back the ribbon cable at the 20 +/- 3mm point.
3
A
18 +/- 3mm
18 +/- 3mm
20 +/- 3mm
Plain side
3-98
C
A
B
Character side
Character side
18 +/- 3mm
90 degree
Plain side
Character side
18 +/- 3mm
Character side
Plain side
20 +/- 3mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Versacamm vs-540iVs-300i