Item
1
NOTE
: User-supplied 24 VDC power supply must incorporate overload protection to limit
peak power to less than 300 W or 8 A in-line circuit protection must be added to the 24 VDC
power source. For multiple robots on a common 24 VDC supply, protect each unit indi-
vidually.
Make sure you select a 24 VDC power supply that meets the specifications provided. Using
an under-rated supply can cause system problems and prevent your equipment from oper-
ating correctly.
2
NOTE
: Specifications established at nominal line voltage. Low line voltage can affect robot
performance.
3
NOTE
: If multiple robots are sharing a 24 VDC power supply, increase the supply capacity
by 3 A for each additional robot.
Facility Overvoltages Protection
You must protect the robot from excessive overvoltages and voltage spikes. If your country
requires a CE-certified installation or compliance with
the installation must ensure that Category II overvoltages (i.e., line spikes not directly due to
lightning strikes) are not exceeded.
Transient overvoltages at the point of connection to the power source shall be controlled not to
exceed overvoltages Category II, i.e., not higher than the impulse voltage corresponding to the
rated voltage for the basic insulation. Your equipment or transient suppressor must be capable
of absorbing the energy in the transient.
In the industrial environment, nonperiodic overvoltage peaks may appear on mains power
supply lines. These can come from power interruptions to high-energy equipment (such as a
blown fuse on one branch in a 3-phase system), which will cause high current pulses at rel-
atively low voltage levels. You must take the necessary steps to prevent damage to the robot
system (such as by interposing a transformer). See

8.5 Environment and Facility Specifications

The robot installation must meet the following operating environment specifications.
Ambient operating temperature
24402-000 Rev B
Specification
OFF response time
Output voltage at inductive
load turnoff (I
= 0.5A,
out
Load = 1 mH)
DC short circuit current
limit
Peak short circuit current
Table 8-6. Robot System Operating Environment Requirements
Item
eCobra 600 and 800 Robots with EtherCAT
Chapter 8: Technical Specifications
Details
only)
60 μsec max., 28 μsec typical (hardware
only)
(+V - 65) ≤ V
demag
0.7A ≤ I
≤ 2.5 A
LIM
I
≤ 4 A
ovpk
 61131-2,
IEC
IEC
61131-4 for additional information.
IEC
Specification
5 to 40°C
5 to 35°C (cleanroom models)
≤ (+V - 45)
61131-2 requires that
147