Carrier 100/A Series Installation, Start-Up, Operating And Service And Maintenance Instructions page 39

4-way multipoise, inducted-combustion gas furnace, input capacities: 45,000 thru 135,000 btuh
Table of Contents

Advertisement

COLOR
AS SHIPPED
Gray
COOL
Yellow
SPARE
Blue
HEAT
Orange
SPARE
Red
CONT FAN
Table 11 - Speed
Selection
SPEED
5
4
3
2
1"
Continuous-blower
speed-as
shipped default
FURNACE
OVERHEATING
HAZARD
Failure
to follow
this caution
may result in reduced
furnace
life.
Recheck
temperature
rise.
It nmst be within
limits specified
on
the
rating
plate.
Recommended
operation
is at the
mid-point
of rise range or slightly
above.
6. Set thermostat
heat anticipator.
a. Mechanical
thermostat
- Set thermostat
heat anticipator
to match
the amp. draw of the electrical
components
in
the R-W
circuit.
Accurate
amp. draw readings
can be
obtained
at the wires normally
connected
to thermostat
subbase
terminals,
R and W. The thermostat
anticipator
should NOT be in the circuit while measuring
current.
(1.) Remove
thermostat from subbase
or from wall.
(2.) Connect
an amp. meter as shown in Fig. 54 across
the R and W subbase
terminals
or R and W wires at
wall.
(3.) Record
amp. draw across terminals
when furnace is
in heating
and after blower
starts.
(4.) Set heat anticipator
on thermostat
per thermostat
instructions
and install on subbase
or wall.
b. Electronic
thermostat:
Set cycle rate for 4 cycles per hr.
7. Adjust
blower
off delay
The
blower
off delay
has
4
adjustable
settings
from 90 sec to 180 sec. The blower
off
delay jumpers
are located
on the furnace
control
board.
(See Fig. 24.)
To change
the blower
off delay setting,
move
the jumper
from one set of pins on the control to the pins used for the
selected
blower
off delay. Factory
off delay setting
is 120
sec.
8. Set airflow
CFM for cooling
Select
the desired
blower
motor
speed
lead for cooling
airflow.
See Table 5-Air
Delivery-CFM
(With Filter). See
Table 11 for lead color identification.
Check
Safety
Controls
The flame sensor,
gas valve,
and pressure
switch were all checked
in the Start-up
procedure
section as part of normal operation.
1. Check Main Limit
Switch(es)
This
control
shuts
off combustion
control
system
and
energizes
air-circulating
blower
motor,
if
furnace
overheats.
By using this method
to check limit control,
it
can be established
that limit is functioning
properly
and
will operate
if there is a restricted
duct system
or motor
failure.
If limit control
does not function
during
this test,
cause nmst be determined
and corrected.
a. Run furnace
for at least 5 minutes.
b. Gradually
block
off return air with a piece of cardboard
or sheet metal until the limit trips.
c. Unblock
return air to permit normal
circulation.
d. Burners
will re-light
when furnace
cools down.
2. Check draft safeguard
switch.
The purpose
of this control
is to cause the safe shutdown
of the furnace
during
certain blocked
vent conditions.
SUBBASE
TERMINALS
WITH
THERMOSTAT
REMOVED
(ANITICIPATOR,
CLOCK,
ETC.,
MUST BE OUT OF CIRCUIT.)
AMMETER
®®®@
10 TURNS
EXAMPLE:
FROM
UNIT 24-V
CONTROL
TERMINALS
5.0 AMPS
ON AMMETER
0.5 AMPS
FOR
THERMOSTAT
=
10 TURNS
AROUND
JAWS
ANTICIPATOR
SETTING
A96316
Fig. 54 - Amp.
Draw
Check
with Ammeter
a. Verify vent pipe is cool to the touch.
b. Disconnect
power
to furnace
and remove vent connector
from furnace
vent elbow.
c. Restore
power to furnace and set room thermostat
above
room temperature.
d. After normal
start-up,
allow
furnace
to operate
for 2
minutes,
then block
vent elbow in furnace
80 percent
of
vent area with a piece of flat sheet metal.
e. Furnace
should cycle offwithin
2 minutes.
If gas does not
shut
off
within
2 minutes,
determine
reason
draft
safeguard
switch
did not function
properly
and correct
condition.
f. Remove
blockage
from furnace
vent elbow.
g. Switch
will auto-reset
when it cools.
h. Re-install
vent connector.
NOTE:
Should
switch
remain
open
longer
than
3 minutes,
furnace
control
board
will lockout
the furnace
for 3 hours.
To
reset
furnace
control
board,
turn
thermostat
below
room
temperature
or from
HEAT
to OFF and turn l15v
power
OFF,
then back ON.
3. Check Pressure
Switch
This control
proves operation
of the draft inducer
blower.
a. Turn off l15-v
power
to furnace.
b. Disconnect
inducer
motor lead wires from wire harness.
c. Turn on l15-v
power
to furnace.
d. Set thermostat
to "call for heat" and wait I minute. When
pressure
switch
is functioning
properly,
hot
surface
igniter
should
NOT glow
and control
diagnostic
light
flashes a status code 32. If hot surface igniter glows when
inducer
motor
is disconnected,
shut
down
furnace
immediately.
e. Determine
reason
pressure
switch
did
not
function
properly
and correct condition.
f. Turn off l15-v
power
to furnace.
g. Reconnect
inducer
motor wires, replace
outer door, and
turn on l15-v
power.
h. Blower
will run for 90 sec before
beginning
the call
forheat again.
i. Furnace
should ignite normally.
39
il

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents