Carrier 100/A Series Installation, Start-Up, Operating And Service And Maintenance Instructions page 18

4-way multipoise, inducted-combustion gas furnace, input capacities: 45,000 thru 135,000 btuh
Table of Contents

Advertisement

Table
5 - Air Delivery
- CFM
(With Filter)*
UNIT SIZE
RETURN-AIR
SUPPLY
SPEED
5
4
045-08/
Bottom
or
3
024045
Side(s)
2
1
5
4
070-16
/
Bottom
or
3
048070
Side(s)
2
1
5
4
090-16
/
Bottom
or
3
048090
Side(s)
2
1
5
4
110-20
/
Bottom
or
3
060110
Side(s)
2
1
5
Bottom
or
4
135-20
/
060135
Side(s)
3
2
1
EXTERNAL STATIC PRESSURE
(In. wc)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1185
1145
1115
1075
1035
980
905
820
720
580
920
880
835
800
755
720
580
545
505
540
735
585
525
585
530
490
435
395
345
295
820
755
725
570
530
580
545
490
455
405
550
595
535
490
430
390
330
280
235
- -
1625
1585
1535
1495
1450
1415
1355
1295
1220
1125
1405
1350
1320
1280
1240
1195
1155
1115
1070
1030
1240
1200
1155
1110
1055
1020
975
935
895
850
1190
1140
1095
1050
1000
955
915
870
830
790
1035
985
930
885
835
785
745
595
550
600
1845
1800
1755
1710
1655
1595
1500
1400
1275
1105
1590
1545
1500
1455
1410
1355
1315
1270
1180
1000
1355
1320
1270
1215
1170
1125
1070
1025
955
900
1225
1160
1110
1060
1010
950
895
830
770
710
1100
1030
950
875
805
730
545
570
505
425
2255
2205
2150
2100
2040
1985
1920
1835
1735
1615
1600
1525
1455
1400
1335
1275
1210
1150
1080
1015
1945
1890
1830
1770
1715
1655
1600
1545
1480
1430
1420
1340
1280
1200
1140
1055
1005
925
855
790
1280
1205
1140
1055
990
910
840
750
595
530
2295
2240
2185
2125
2070
2005
1925
1805
1670
1545
1725
1650
1605
1545
1450
1395
1340
1285
1230
1170
1910
1855
1800
1745
1685
1610
1545
1485
1435
1380
1630
1575
1510
1435
1355
1300
1245
1185
1130
1055
1430
1355
1285
1200
1125
1075
1015
945
855
800
*A filter is required for each return-air
inlet. Airflow performance
included
3/4-in.
(19 mm) washable filter media such as contained
in factory-authorized
accessory filter rack. To determine
airflow performance
without this filter, assume an additional
0.1 in. wc available external static pressure.
--
Indicates unstable
operating
conditions.
Table 6 - Maximum
Capacity
of Pipe*
NOMINAL
iRON
iNTERNAL
LENGTH OF PiPE - FT. (M)
PiPE
DIAMETER
SIZE IN. (mm)
In. (mm)
10
20
30
40
50
1/2 (13)
0.822 (16)
175 (53)
120 (37)
97 (30)
82 (25)
73 (22)
3/4 (19)
0.824 (21)
380 (110)
250 (76)
200 (61)
170 (52)
151 (46)
1 (25)
1.049 (27)
680 (207)
465 (142)
375 (114)
320 (98)
285 (87)
1-1/4
(32)
1.380 (35)
1400 (427)
950 (290)
770 (235)
680 (201)
580 (177)
1-1/2
(38)
1.810 (41)
2100 (640)
1460 (445)
1180 (380)
990 (301)
900 (274)
Cubic ft. of natural gas per hr for gas pressures of 0.5 psig (14-in.
wc) or less and a pressure drop of 0.5-in
wc (based on a 0.60 specific gravity
gas). Ref: Chapter 6 ANSI Z223-2006/NFPA
54-2006.
Piping should be pressure and leak tested in accordance with
NFGC in the United States or CAN/CSA-B149.1-05
in Canada,
local, and national plumbing and gas codes before the furnace has
been connected. After all connections have been made, purge
lines and check for leakage at furnace prior to operating furnace.
If pressure exceeds 0.5 psig (14-in. wc), gas supply pipe must be
disconnected from furnace and capped before and during supply
pipe pressure test. If test pressure is equal to or less than 0.5 psig
(14-in. wc), turn off electric shutoff switch located on furnace gas
control valve and accessible manual equipment shutoff valve
before and during supply pipe pressure test. After all connections
have been made, purge lines and check for leakage at furnace
prior to operating furnace.
The gas supply pressure shall be within the maximum
and
minimum inlet supply pressures marked on the rating plate with
the furnace burners ON and OFF.
18