Connecting A Keyboard Wedge Interface - Wasp Duraline WLS 8400 ER Series Product Reference Manual

Wasp bar code industrial scanner product reference guide
Hide thumbs Also See for Duraline WLS 8400 ER Series:
Table of Contents

Advertisement

5-4
WLS 8400 Product Reference Guide

Connecting a Keyboard Wedge Interface

Figure 5-1. Keyboard Wedge Interface Connection with Y-cable
To connect the keyboard wedge interface Y-cable:
Interface cables vary depending on configuration. The connectors
illustrated in
different than those illustrated, but the steps to connect the scanner
remain the same.
1. Turn off the host and unplug the keyboard connector.
2. Attach the modular connector of the Y-cable to the cable interface port on the
scanner. (See
3. Connect the round male DIN host connector of the Y-cable to the keyboard port on
the host.
4. Connect the round female DIN keyboard connector of the Y-cable to the keyboard
connector.
5. If required, attach the optional power supply to the connector in the middle of the
Y-cable.
6. Ensure that all connections are secure.