Invacare® Pronto™ M41 Series with SureStep®
1. Loosen screws A.
Do not remove them.
2. Adjust arm pad to desired angle.
3. Tighten screws.
5.5.8 Adjusting the position of the arm pad of the flip-up
armrest
•
5 mm Allen key
1. Put the armrest in the vertical position.
2. Release the interior bolts (1) with the Allen key.
38
3.
Position the armrest horizontally.
4. Re-tighten the bolts.
Make sure that the Nordlock washers used are
re-inserted.
5.5.9 The hip support
The hip support can be combined with the flip-up armrest
only.
1553378-G