12.
With the open end of the wheel facing up, fill
the area inside the wheel around the axle full of
general-purpose grease.
13.
Insert the second bearing and new seal into the
wheel.
14.
Apply a thread-locking adhesive to the second
spacer nut, and thread it onto the axle with the
wrench flats facing outward.
15.
Torque the nut to 8 to 9 N∙m (75 to 80 in-lb),
loosen, then torque to 2 to 3 N∙m (20 to 25 in-lb).
Note:
Ensure that the axle does not extend
beyond the nut.
16.
Install the seal guards over the wheel hub, and
insert wheel into the caster fork.
17.
Install the caster bolt and tighten the nut fully.
Important:
To prevent seal and bearing damage,
check the bearing adjustment often. Spin the
caster tire. The tire should not spin freely (more
than 1 or 2 revolutions) or have any side play. If
the wheel spins freely, adjust the torque on the
spacer nut until there is a slight amount of drag.
Apply another layer of thread-locking adhesive.

Engine Maintenance

WARNING
Contact with hot surfaces may cause personal
injury.
Keep hands, feet, face, clothing, and other
body parts away the muffler and other hot
surfaces.

Servicing the Air Cleaner

Service Interval: Every 100 hours
Every 200 hours/Yearly (whichever comes
first)—Replace the primary air filter (more often
in dusty or sandy conditions).
Every 250 hours—Check the inner air filter.
Every 500 hours—Replace the inner air filter.
Note:
Check the filters more frequently if the
operating conditions are extremely dusty or sandy.
Removing the Filters
1.
Disengage the PTO, move the motion-control
levers to the
NEUTRAL
parking brake.
2.
Shut off the engine, remove the key from the
ignition, and wait for all moving parts to stop
before leaving the operating position.
3.
Release the latches on the air cleaner, and
pull the air-inlet cover off the air-cleaner body
(Figure
45).
4.
Clean the air-inlet screen and cover.
5.
Install the air-inlet cover and secure it with the
latches
(Figure
1. Air-inlet cover
2. Air-inlet screen
37
-
position, and set the
LOCK
45).
Figure 45
3. Air-cleaner body
4. Latch
g012996

Advertisement